WBGT heat stress calculator

Indoors, WBGT = 0.7 Tnwb + 0.3 Tg. Outdoors in sun, WBGT = 0.7 Tnwb + 0.2 Tg + 0.1 Ta. Add the clothing adjustment and compare the result with the NIOSH limit for the work rate and acclimatization.

Measured temperatures
Location
°C
°C
°C
Worker and clothing
Acclimatized?
WBGT
-
°C
Effective WBGT
-
°C
Limit
-
°C

Screening calculation. Results support, and do not replace, a qualified person's judgment and the applicable standard.

Wet bulb globe temperature (WBGT) combines air temperature, humidity, air movement and radiant heat into one number. Measure natural wet bulb (Tnwb) and black globe (Tg) temperatures, plus air temperature (Ta) outdoors, then compare the WBGT with the limit for the work rate. NIOSH gives a Recommended Exposure Limit (REL) for acclimatized workers and a Recommended Alert Limit (RAL) for workers who are not.

WBGT formulas

Indoors or no solar load: WBGT = 0.7 Tnwb + 0.3 Tg

Outdoors with solar load: WBGT = 0.7 Tnwb + 0.2 Tg + 0.1 Ta

These are the weightings in NIOSH's heat stress criteria (publication 2016-106). They need measured natural wet-bulb and globe temperatures from a WBGT meter. Calculators that estimate WBGT from weather data, such as OSHA's and the National Weather Service's, are useful for planning but cannot see the radiant heat from a furnace or a sun-baked roof.

NIOSH limits by work rate

REL (acclimatized) = 56.7 − 11.5 log₁₀(M)   ·   RAL (unacclimatized) = 59.9 − 14.1 log₁₀(M)

Work rateMetabolic rate MRELRALExamples
Light180 W30.8 °C28.1 °CLight hand work, slow walking
Moderate300 W28.2 °C25.0 °CSustained arm work, normal walking
Heavy415 W26.6 °C23.0 °CShoveling, sawing hardwood
Very heavy520 W25.5 °C21.6 °CClimbing stairs with a load, heavy digging

Clothing adjustment

Protective clothing traps heat, so a clothing adjustment factor is added to the measured WBGT before comparing it with the limit: 0.5 °C for SMS polypropylene coveralls, 1 °C for polyolefin coveralls and 3 °C for double-layer woven clothing. For vapor-barrier and fully encapsulating suits, WBGT limits may not protect workers at all. Use physiological monitoring instead.

Worked example

An acclimatized crew is doing moderate work outdoors in sun in normal work clothes. The meter reads Tnwb 26 °C, Tg 45 °C and Ta 33 °C. WBGT = 0.7 × 26 + 0.2 × 45 + 0.1 × 33 = 30.5 °C, which is 2.3 °C over the REL of 28.2 °C for 300 W. The crew needs shade, water, rest breaks and a slower pace, or the heaviest work moved to a cooler part of the day.

Questions

What is the difference between the NIOSH REL and RAL?

The REL applies to workers who are acclimatized to heat. The RAL is lower and applies to workers who are new or returning after time away, typically for their first one to two weeks.

Can I calculate WBGT from temperature and humidity alone?

Only as an estimate. Temperature and humidity miss radiant heat and the effect of wind on a natural wet-bulb thermometer. A WBGT meter gives the measured values this calculator expects.

Is there an OSHA heat standard?

OSHA has cited heat hazards under the General Duty Clause and runs a heat National Emphasis Program, and several states have their own heat rules. Check the current federal and state requirements for your site; NIOSH criteria are the usual technical basis for limits.