An 8-hour time-weighted average (TWA) is the average concentration over a work shift, weighted by how long each concentration lasted. Multiply each sample result by its duration in minutes, add the products and divide by 480. Compare the TWA with the 8-hour limit for that substance.
The TWA formula
TWA = (C₁t₁ + C₂t₂ + … + Cₙtₙ) ÷ 480 min
This is the formula in OSHA's air contaminants standard, 29 CFR 1910.1000(d). It assumes the samples cover the whole shift, or that the worker was not exposed during the unsampled time. When sampling misses part of the shift, you have to decide what that time represents.
Unsampled time
- Same as the sampled average. The conservative choice, and the default here. The TWA equals the average of the samples.
- Zero exposure. Divides by the full shift, so unsampled time counts as no exposure. Use it only with evidence that the worker was away from the source, such as a lunch break off site.
- Sampled period only. Reports the average without claiming a full-shift TWA. Do not compare it directly with an 8-hour limit.
Worked example
Three samples cover 7 of 8 hours: 12 ppm for 120 minutes, 30 ppm for 180 minutes and 8 ppm for 120 minutes. The sampled average is (1,440 + 5,400 + 960) ÷ 420 = 18.6 ppm. Treating the missing hour as equal to the samples, the TWA is 18.6 ppm, 93% of a 20 ppm limit. If the worker was demonstrably away from the source for that hour, the zero-exposure TWA is 7,800 ÷ 480 = 16.3 ppm, 81% of the limit. Both results fall in the action level band.
Exposure bands
| Percent of limit | Band | Typical response |
|---|---|---|
| Under 10% | Well controlled (AIHA category 1) | Routine reassessment |
| 10 to 50% | Acceptable (AIHA category 2) | Periodic monitoring |
| 50 to 100% | Action level (AIHA category 3) | More sampling, review of controls; many OSHA substance standards set the action level at half the PEL |
| 100% or more | Overexposed (AIHA category 4) | Controls and respiratory protection as required |
Many OSHA substance-specific standards, such as benzene, set an action level at one-half of the PEL, but not all do, so check the standard for the substance you sampled. Shifts longer than 8 hours may also need an adjusted limit.
Questions
Can I average samples that were taken on different days?
No. A TWA describes one worker on one shift. Results from different days are separate data points for an exposure profile.
What if my samples cover less than the full shift?
Decide how to treat the unsampled time and document it. Assuming it matches the sampled average is the conservative choice; assuming zero exposure needs evidence that the worker was away from the source.
Does this work for STEL or ceiling limits?
No. STELs are 15-minute averages and ceilings must never be exceeded, so compare those samples directly with the limit rather than folding them into an 8-hour TWA.