Measurement Tools
Sound Level Meter, Light Meter, Vibration Meter, Anemometer, and WBGT Calculator using device sensors with Bluetooth integration support.
Built by CIH/CSP Professionals • Field-Tested
The complete industrial hygiene and occupational health toolkit featuring 35+ professional measurement tools, international exposure limit databases, and comprehensive exam preparation modules.
OSHA and NIOSH criteria, using the same equations IH Toolbox ships with. Enter each level you measured and how long you were in it.
Sound Level Meter, Light Meter, Vibration Meter, Anemometer, and WBGT Calculator using device sensors with Bluetooth integration support.
IH Equation Solver, NIOSH Lifting Equation, Ventilation Rate Calculator, Fall Clearance, Chemical Mixture TLV, and Scientific Calculator.
Access 25+ occupational exposure limit references including OSHA PEL, NIOSH REL, Cal/OSHA, UK WEL, Australia WES, and more.
All measurements automatically tagged with GPS location data for comprehensive field documentation and reporting.
NIOSH Pocket Guide, Respiratory Protection Guide, Fire Extinguisher Selector, Chemical Storage Guide, and Safety Sign Decoder.
A tab for the work around the numbers. Organize surveys into projects and sites, log air, noise, wipe and bulk samples, and see at a glance what is running and what is waiting on a lab.
Save a plan from the Air Sampling Planner and start a run from it. The clock handles pauses, and the pre/post calibration pair is checked against the 5% drift limit most NIOSH methods allow.
Enter what the lab reported and get the calculated exposure against the applicable limit — with Brief & Scala or OSHA shift adjustment, explicit handling of unsampled time, and a plain-language explanation of how the number was reached.
Import results from any laboratory’s CSV by mapping its columns once. Instruments are recorded by make, model and serial number, so the record never depends on whose hardware or whose lab you used.
Readings taken with the phone’s own sensors are marked as field screening throughout, and on every page of an exported report. They are never presented as compliance documentation.
Generate a multi-page exposure survey report: sample summary, the full chain behind each result, and an appendix stating the assumptions applied so the numbers can be reproduced.
CIH and CSP question banks are included in Pro — no longer a separate purchase. Anyone who already bought the standalone add-on keeps their access permanently.
Built for the people who actually take the readings
CIHs and IH technicians running walkthrough surveys, noise dosimetry, and heat stress assessments who need defensible numbers without hauling a full instrument kit to a scoping visit.
Site safety leads who need a fast, credible answer on ventilation, confined space entry, or an ergonomics complaint before deciding whether a formal survey is warranted.
Bioenvironmental engineering and preventive medicine teams working blast overpressure, WBGT, and non-ionizing radiation in the field, often without connectivity.
Independent IH consultants who bill by the hour and need GPS-tagged measurements and PDF exports that go straight into a client report.
Certification candidates using the calculators and reference library to build intuition for the equations and exposure limits the exams actually test.
Plant and facilities staff verifying containment pressure differentials, lighting levels, and airflow between formal assessments.



No, and it is not marketed as a substitute for calibrated, certified equipment. The sound level meter, light meter, and environmental tools use your device's sensors, which makes them excellent for screening, scoping, and triage — deciding where a full survey is warranted. For compliance sampling and any measurement that becomes a legal record, use calibrated instrumentation.
35+ tools across measurement, calculation, and reference. That covers a sound level meter with TWA and A-weighting, WBGT heat stress with weather integration, light meter, anemometer, vibration, blast overpressure, pressure differential, UV and cold stress, plus specialty modules for radiation, non-ionizing radiation, chemical mixture OELs by the ACGIH TLV method, air sampling planning, ventilation, confined space, and RULA/REBA ergonomics.
Yes. The reference library — 25+ global OEL standards including OSHA, NIOSH, and international sources, plus respiratory protection guidance and chemical compatibility data — is bundled in the app. Measurements and calculations run offline. Only weather-integrated WBGT inputs need a connection.
PDF and CSV export are built in, and measurements are GPS-tagged so locations stay tied to readings. iCloud sync keeps work in step across your devices.
Pro is a single lifetime purchase covering everything in the app, with a discounted price for verified service members. Calculators, live meters, OSHA PEL references and checklist templates stay free, and you can save three measurement sessions before Pro is needed. CIH and CSP exam prep is included in Pro rather than sold separately.
Yes, as of version 2.5. Projects organize surveys into sites, and a saved plan from the Air Sampling Planner can be started as a live run — the clock handles pauses, and the pre/post calibration pair is checked against the 5% drift limit most NIOSH methods allow. Enter the lab result and you get the calculated exposure against the applicable limit, with Brief & Scala or OSHA shift adjustment and explicit handling of unsampled time.
No. Readings taken with the phone’s own sensors are labelled as field screening everywhere they appear, including on every page of an exported report. Lab-analyzed results and phone screening are kept visibly distinct, so the two never get conflated in documentation.
Microphone for sound level and dosimetry, camera for light metering, barometer for pressure differential, and the motion sensors for vibration. Accuracy depends on your device hardware, so calibrate against a known reference when the number matters.