Fouled Anchor Safety logoFouled Anchor SafetyFAS-01
FAS-01 / Free tools / Noise dose and TWA calculator
Free calculator · runs in your browser

Noise dose and TWA calculator

Dose = 100 × Σ(C ÷ T), where T is the allowed time at each level. OSHA uses a 90 dBA criterion and a 5 dB exchange rate; NIOSH uses 85 dBA and 3 dB. Enter each period of the shift to see both, then check the hearing protection.

Exposure periods
Level (dBA)HoursAllowed OSHA / NIOSH
-
-
-

Hearing protection
dB
OSHA PEL dose
-
%
TWA
-
dBA
OSHA action-level dose
-
%
TWA
-
dBA
NIOSH dose
-
%
TWA
-
dBA
Derated NRR
-
dB
Protected TWA
-
dBA

Screening calculation. Results support, and do not replace, a qualified person's judgment and the applicable standard.

Noise dose is the share of the allowed daily exposure a worker receives. For each level, divide the time spent there by the allowed time at that level, add the fractions and multiply by 100. Under OSHA, 100% dose equals a 90 dBA 8-hour TWA (the PEL) and 50% equals 85 dBA (the action level).

Dose and TWA formulas

D = 100 × (C₁/T₁ + C₂/T₂ + … + Cₙ/Tₙ)

OSHA (29 CFR 1910.95)NIOSH REL
Allowed time T8 ÷ 2^((L − 90) ÷ 5)8 ÷ 2^((L − 85) ÷ 3)
TWA from dose16.61 log₁₀(D ÷ 100) + 9010 log₁₀(D ÷ 100) + 85
Criterion level90 dBA85 dBA
Exchange rate5 dB3 dB
Levels counted90 dBA and up for the PEL; 80 dBA and up for the action level80 dBA and up

OSHA computes two doses. The PEL dose counts only levels of 90 dBA and up (Table G-16). The action-level dose counts everything from 80 dBA, and a result of 50% or more (an 85 dBA TWA) triggers the hearing conservation program: monitoring, annual audiograms, hearing protectors and training.

Worked example

A mechanic spends 2 hours at 95 dBA, 4 hours at 88 dBA and 2 hours at 82 dBA. The OSHA PEL dose counts only the 95 dBA time: 2 ÷ 4 = 50%, a TWA of 85.0 dBA. The action-level dose adds the 88 and 82 dBA time and reaches 96.1%, a TWA of 89.7 dBA. The mechanic is below the PEL but well inside the hearing conservation program. Under NIOSH's criteria the same day is a 364.5% dose, a TWA of 90.6 dBA. The 3 dB exchange rate counts high levels much more heavily.

Hearing protector NRR derating

Protected TWA ≈ TWA(dBA) − (NRR − 7) × 50%   ·   plugs and muffs: higher derated NRR + 5 dB

Labeled Noise Reduction Ratings come from laboratory fits that workers rarely match. When exposure is measured in dBA, OSHA subtracts 7 dB from the NRR (Appendix B of 29 CFR 1910.95), and OSHA's Technical Manual then applies a 50% safety factor. Wearing plugs and muffs together adds about 5 dB to the better of the two. In the example, a foam plug with an NRR of 29 gives (29 − 7) ÷ 2 = 11 dB, so the protected exposure is about 78.7 dBA. OSHA requires protectors to bring exposure to 90 dBA or below, and to 85 dBA or below for workers with a standard threshold shift.

Questions

What noise dose requires a hearing conservation program?

Under OSHA, an 8-hour TWA of 85 dBA or more, which is a 50% dose using the action-level method (all levels from 80 dBA counted).

Why are the OSHA and NIOSH results so different?

NIOSH uses an 85 dBA criterion and a 3 dB exchange rate, so each 3 dB increase halves the allowed time. OSHA halves it every 5 dB. For the same exposure, the NIOSH dose is usually much higher.

Why derate the NRR?

The label is measured in a laboratory with an ideal fit. Field studies show workers get much less, so OSHA subtracts 7 dB for A-weighted measurements and then takes half of what remains.