Noise dose is the share of the allowed daily exposure a worker receives. For each level, divide the time spent there by the allowed time at that level, add the fractions and multiply by 100. Under OSHA, 100% dose equals a 90 dBA 8-hour TWA (the PEL) and 50% equals 85 dBA (the action level).
Dose and TWA formulas
D = 100 × (C₁/T₁ + C₂/T₂ + … + Cₙ/Tₙ)
| OSHA (29 CFR 1910.95) | NIOSH REL | |
|---|---|---|
| Allowed time T | 8 ÷ 2^((L − 90) ÷ 5) | 8 ÷ 2^((L − 85) ÷ 3) |
| TWA from dose | 16.61 log₁₀(D ÷ 100) + 90 | 10 log₁₀(D ÷ 100) + 85 |
| Criterion level | 90 dBA | 85 dBA |
| Exchange rate | 5 dB | 3 dB |
| Levels counted | 90 dBA and up for the PEL; 80 dBA and up for the action level | 80 dBA and up |
OSHA computes two doses. The PEL dose counts only levels of 90 dBA and up (Table G-16). The action-level dose counts everything from 80 dBA, and a result of 50% or more (an 85 dBA TWA) triggers the hearing conservation program: monitoring, annual audiograms, hearing protectors and training.
Worked example
A mechanic spends 2 hours at 95 dBA, 4 hours at 88 dBA and 2 hours at 82 dBA. The OSHA PEL dose counts only the 95 dBA time: 2 ÷ 4 = 50%, a TWA of 85.0 dBA. The action-level dose adds the 88 and 82 dBA time and reaches 96.1%, a TWA of 89.7 dBA. The mechanic is below the PEL but well inside the hearing conservation program. Under NIOSH's criteria the same day is a 364.5% dose, a TWA of 90.6 dBA. The 3 dB exchange rate counts high levels much more heavily.
Hearing protector NRR derating
Protected TWA ≈ TWA(dBA) − (NRR − 7) × 50% · plugs and muffs: higher derated NRR + 5 dB
Labeled Noise Reduction Ratings come from laboratory fits that workers rarely match. When exposure is measured in dBA, OSHA subtracts 7 dB from the NRR (Appendix B of 29 CFR 1910.95), and OSHA's Technical Manual then applies a 50% safety factor. Wearing plugs and muffs together adds about 5 dB to the better of the two. In the example, a foam plug with an NRR of 29 gives (29 − 7) ÷ 2 = 11 dB, so the protected exposure is about 78.7 dBA. OSHA requires protectors to bring exposure to 90 dBA or below, and to 85 dBA or below for workers with a standard threshold shift.
Questions
What noise dose requires a hearing conservation program?
Under OSHA, an 8-hour TWA of 85 dBA or more, which is a 50% dose using the action-level method (all levels from 80 dBA counted).
Why are the OSHA and NIOSH results so different?
NIOSH uses an 85 dBA criterion and a 3 dB exchange rate, so each 3 dB increase halves the allowed time. OSHA halves it every 5 dB. For the same exposure, the NIOSH dose is usually much higher.
Why derate the NRR?
The label is measured in a laboratory with an ideal fit. Field studies show workers get much less, so OSHA subtracts 7 dB for A-weighted measurements and then takes half of what remains.